Startseite/ Industries/ Subsea Solutions
Subsea Solutions

Grit-Free Surface Preparation Below the Waterline

Engineered for underwater environments, diving operations, and offshore maintenance, delivering controlled surface conditioning even in demanding subsea conditions.

Extreme environments

Below the surface

When corrosion protection needs to extend below the surface of the sea, precision, safety, and reliability become even more critical.

“Grit-free preparation, controlled even below the waterline.”

Water pressure

Managing buoyancy and pressure effects at depth.

Limited visibility

Operating in murky or restricted subsea environments.

Environmental risk

Preventing contamination in sensitive marine ecosystems.

Operational constraints

Meeting strict diving campaign and ROV requirements.

The subsea advantage

Hydraulic power, underwater integrity

The Bristle Blaster® Subsea is a hydraulic underwater device with a unique water drive. Connected via a single, neutrally buoyant high-pressure hose, it creates a controlled, inspectable surface profile below the waterline, without grit or containment. Topside, the same principle runs on the Bristle Blaster® range.

Underwater surface preparation
Underwater surface preparation
Bristle Blaster® SubseaSubsea beltsSubsea surface preparation
Our subsea offering

Our subsea offering

Diving-compatible tools

Specialized surface preparation tools operated safely by commercial divers.

Caviblasting systems

Advanced water-based blasting that delivers controlled cleaning underwater.

Technical support

From pre-project planning to offshore execution, our specialists support the campaign.

Subsea applications

Where it's used

Offshore platforms & jackets

Controlled, inspectable preparation on structural steel.

Subsea pipelines & spools

Grit-free conditioning for reliable coating adhesion.

Marine vessels

Underwater hull sections and structures.

Wind foundations

Offshore wind foundation maintenance.

FPSO structures

Floating production, storage and offloading structures.

IRM campaigns

Inspection, repair, and maintenance campaigns.

Bristle Blaster® Subsea

Prepared below
the waterline.

Vorbereitung unter Wasser field application
Im Feld bewährt

Weltweit auf Projekten vertraut

The water-driven Bristle Blaster® enables hydraulic underwater surface preparation where conventional blasting cannot reach.

Subsea contractorsOffshore support vessel operatorsMarine engineering firms
See it in action

Surface preparation, underwater

The water-driven Bristle Blaster® prepares submerged steel where conventional blasting can't reach.

Zertifiziert für explosionsgefährdete Bereiche

Spark-free surface prep for subsea and splash-zone hot-work zones.

The Bristle Blaster® Pneumatic Ultimate has undergone an independent Gexcon ignition-hazard analysis and ATEX 2014/34/EU conformity evaluation, so coating repair can continue in hazardous offshore areas without electric-tool hot-work permits.

◎ Ex
II 2G Ex h IIA Gb · II 2D Ex h IIIC Db
Kategorie 2, Zone 1 Gas & Zone 21 Staub

Explosionsfähiges Gas, Zone 1, bewertet für Gasgruppe IIA (Benzin, Hexan, Propan), EPL Gb.

Explosionsfähiger Staub, Zone 21, bewertet für Staub-Untergruppe IIIC, EPL Db.

Vollpneumatisch: Druckluftantrieb, keine elektrischen Komponenten, keine elektrische Zündquelle.

Unabhängig bewertet durch Gexcon nach der harmonisierten Normenreihe EN ISO 80079.

EN ISO 80079-36:2016 EN ISO 80079-37:2016 IEC 60079-0 ATEX 2014/34/EU
ATEX certified Bristle Blaster® Pneumatic Ultimate
Gerätegruppe / KategorieII 2G & II 2D
GasatmosphäreZone 1 · IIA · EPL Gb
StaubatmosphäreZone 21 · IIIC · EPL Db
AntriebPneumatisch, keine Elektrik
ZündschutzartenKonstruktive Sicherheit „c“ · Zündquellenüberwachung „b“
BewertungGexcon IHA · rev 02 · 2026
Unabhängig durch physische Prüfungen bei Gexcon verifiziert
EN 80079-36 Annex DKeine elektrostatische Entladung

Die Prüfung auf Büschelentladung ergab keine messbare Entladung, bestanden für die Gasgruppen IIA, IIB und IIC.

ISO 80079-36 · IEC 60079-0Falltest bestanden, Sicherheit erhalten

Acht Stürze bei Umgebungs- und Frosttemperatur, keine Schäden, die die Zündsicherheit des Werkzeugs mindern.

ATEX 2014/34/EUKeine Zündung in explosiven Gaswolken

Betrieb in explosiven Propan-Luft-Atmosphären (Gruppe IIA), ohne beobachtete Zündung.

Markings shown reflect the scope of the independent ATEX conformity evaluation. Confirm the certified marking on the tool nameplate and Declaration of Conformity for your specific configuration before specifying.

BASFEnbridgeConocoPhillipsDowEnBWCarbolineKansai PaintBelzonaSherwin-WilliamsChestertonHempelCanusa-CPSStopaqInternational PaintAkzoNobelPPGLoctiteProtegol (TIB Chemicals)AllterPolykenZingaCovalence3X EngineeringJotunChugoku Marine Paints
HSE & quality

IMCA, DNV & ISO aligned

MontiPower subsea tools are configured in accordance with offshore safety standards and industry diving protocols. IMCA-compliant, built to DNV offshore requirements, and compliant with relevant ISO standards.